Mediterranea

Latest Generation HPLC Column

Moreover, the mediterranea™ sea18 column has been designed to show an excellent retention of polar compounds in a 100% aqueous environment without the problems of unwanted interactions which inefficiently endcapped conventional packings produce. Packing chemistry based on the new MED technology, “multifunctional endcapping deactivated”, achieves levels of deactivation, resistance to extreme pH values and versatility in its chromatographic applications never reached by conventional or polar-embedded reverse phase packings.The MED technology has been rigorously developed to achieve the maximum reproducibility, with the objective that its chromatographic separations will be, column to column, exactly the same.

An essential condition for obtaining the global-best reverse phase packing is an extremely pure silica. The silica particle, on which the new mediterranea™ sea18 packing is based, is obtained from ultra-pure materials, using rigorously controlled manufacturing processes to ensure that the slightest possibility of contamination is avoided. The mediterranea™ sea18 silica required intensive optimisation of numerous processing factors to achieve a perfectly spherical, rigid and inert particle possessing unusually low metal content. The almost total absence of metals is one of the pillars over which the extraordinary properties of the mediterranea™ sea18 column reside.

NIST Test
Wide pH range
APPLICATIONS IN 100% AQUEOUS MEDIA
Applications
Guardcolumns
Downloads

NIST test for HPLC packings characterisation

The NIST test uses a mixture of five organic compounds (uracil, toluene, ethylbenzene, quinizarin and amitriptyline).

Uracil is an indicator of column dead volume (non-retained peak).

Toluene/Ethylbenzene the selectivity factor between these two compounds can be used to characterise differences between packings mainly due to hydrophobic interactions.

Quinizarine measures the activity towards chelating reagents.

Amitriptyline measures activity towards bases. It is an excellent indicator of the activity of residual silanols on the surface of the packaging.

 

The Mediterranean Sea 18 column has been subjected to the SRM870 test. This test designed by NIST, is currently considered to be the most recommended test for evaluating the most significant properties of a reversed phase column

 

The mediterranea ™ sea18 packing consists of perfectly spherical particles, a fully controlled pore design, silica completely free of trace metals and a carefully designed phase bonding process and final end-capping, a packing with a previously unachieved resistance to extreme pH values has been achieved.

The columns with mediterranea ™ sea18 fillers allow you to work with eluents from pH 1 to pH 12. This unusual resistance to pH values has been ensured as a result of efficient phase bonding and a patented end-capping process that provides a shield protection that prevents acidic and basic eluents from attacking the silica surface.

The pH stability graphs show the efficiency of the process.

With an eluent as acidic as pH 1, the column stabilizes in a short period of time so that it is even possible to work under these extreme conditions.

 

Eluting the Mediterranean ™ sea18 column for 78 hours at pH 11.5 showed no significant deterioration in terms of efficiency and peak symmetry for diphenhydramine.

 

The mediterranea sea18 is a 100 % pure reverse phase packing with the additional advantage that it has an excellent retention of polar compounds and also allows working with 100 % aqueous mobile phases without any limitations.

It is known that fillers known as "polar embedded" have in principle the advantage over conventional fillers in that they can work in 100% aqueous media and also show good behavior towards basic compounds.

However, these advantages are achieved at the expense of a lower retention of polar compounds and a lower stability of the column, and of a chromatographic behavior that cannot be considered 100% reversed phase, since secondary interaction mechanisms can coexist, which will be marked by the special nature of the polar functional groups anchored at the base of the hydrocarbon chains.

The mediterranea sea18 packing significantly exceeds all the advantages of "polar embedded" packings and does not show any of their disadvantages. Moreover, thanks to its specially optimized endcapping process (MED), extreme strength and lifetime of the column is guaranteed.

As can be seen, the chromatograms obtained after eluting the column with 100% water for more than 40 hours show no appreciable alteration in the retention times or in the efficiency of the chromatographic peaks.

The Mediterranean ™sea18 column also passes the Stop Flow test, designed to highlight the "deweting" phenomenon that usually occurs in highly deactivated ODS type columns and which consists of the irreversible expulsion of the water included in the pores of the packing.

The table shows the retention times for different chromatographic peaks before and after passing the "Stop Flow" test. After 5 consecutive cycles, no significant alterations of the retention times are observed.

Clinics and Bioanalysis
Aminopyridines
Anti-HIV Agents
Choose your product
showing 20 of 163 products
Length
0,4 cm (1)
10 cm (29)
100 mm (7)
125 mm (3)
15 cm (30)
150 mm (5)
20 cm (11)
200 mm (1)
25 cm (22)
250 mm (2)
3 cm (9)
30 mm (1)
300 mm (5)
4 cm (4)
40 mm (2)
5 cm (20)
50 mm (1)
7,5 cm (5)
75 mm (4)
Column ID
10 mm (5)
2,1 mm (26)
21,2 mm (6)
3,0 mm (26)
4,0 mm (48)
4,6 mm (42)
7,8 mm (9)
Technology
Reverse Phase (154)
Support
Silica (163)
Brand
Mediterranea (163)
Function
Sea 18 (93)
Sea 4 (15)
Sea 8 (53)
Type
Analytical (86)
Microbore (48)
Preparative (8)
Semipreparative (12)
Pore Size
100 Å (153)
120 Å (1)
Particle Size
1,8 µm (10)
2,2 µm (12)
3 µm (54)
4 µm (1)
5 µm (85)
Format
Cartridge (14)
Column (147)
Reference TR-010000
Description Mediterranea Sea18 Column 5µm 3 x 0,46 cm
Price 472,03€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010001
Description Mediterranea Sea18 Column 5µm 4 x 0,46 cm
Price 490,17€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010002
Description Mediterranea Sea18 Column 5µm 5 x 0,46 cm
Price 508,33€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010003
Description Mediterranea Sea18 Column 5µm 10 x 0,46 cm
Price 571,54€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010004
Description Mediterranea Sea18 Column 5µm 15 x 0,46 cm
Price 616,90€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010005
Description Mediterranea Sea18 Column 5µm 20 x 0,46 cm
Price 659,78€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010006
Description Mediterranea Sea18 Column 5µm 25 x 0,46 cm
Price 665,66€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010007
Description Mediterranea Sea18 Column 5µm 3 x 0,40 cm
Price 472,03€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010008
Description Mediterranea Sea18 Column 5µm 4 x 0,40 cm
Price 490,17€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010009
Description Mediterranea Sea18 Column 5µm 5 x 0,40 cm
Price 508,33€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010010
Description Mediterranea Sea18 Column 5µm 10 x 0,40 cm
Price 571,54€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010011
Description Mediterranea Sea18 Column 5µm 15 x 0,40 cm
Price 616,90€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010012
Description Mediterranea Sea18 Column 5µm 20 x 0,40 cm
Price 659,78€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010013
Description Mediterranea Sea18 Column 5µm 25 x 0,40 cm
Price 665,66€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010015
Description Mediterranea Sea18 Column 5µm 5 x 0,21 cm
Price 548,37€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010016
Description Mediterranea Sea18 Column 5µm 10 x 0,21 cm
Price 654,56€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010017
Description Mediterranea Sea18 Column 5µm 15 x 0,21 cm
Price 687,63€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010018
Description Mediterranea Sea18 Column 5µm 20 x 0,21 cm
Price 712,01€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010019
Description Mediterranea Sea18 Column 5µm 3 x 0,30 cm
Price 501,52€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
Reference TR-010020
Description Mediterranea Sea18 Column 5µm 5 x 0,30 cm
Price 548,37€
Quantity
To be able to buy you must be registered Sign up
To use the Favorites List you must be registered Sign up
showing 20 of 163 products
Teknokroma

HPLC Cartridge Guard column

Precolumns for analitical and microbore columns